	Fixed a typo in "threshold" word
This commit is contained in:
		| @@ -127,7 +127,7 @@ fi | ||||
|  | ||||
| # Log the fan speed objective, CPU temperature threshold and check interval | ||||
| echo "Fan speed objective: $DECIMAL_FAN_SPEED%" | ||||
| echo "CPU temperature treshold: $CPU_TEMPERATURE_TRESHOLD°C" | ||||
| echo "CPU temperature threshold: $CPU_TEMPERATURE_THRESHOLD°C" | ||||
| echo "Check interval: ${CHECK_INTERVAL}s" | ||||
| echo "" | ||||
|  | ||||
| @@ -166,10 +166,10 @@ while true; do | ||||
|   retrieve_temperatures $IS_EXHAUST_TEMPERATURE_SENSOR_PRESENT $IS_CPU2_TEMPERATURE_SENSOR_PRESENT | ||||
|  | ||||
|   # Define functions to check if CPU 1 and CPU 2 temperatures are above the threshold | ||||
|   function CPU1_OVERHEAT () { [ $CPU1_TEMPERATURE -gt $CPU_TEMPERATURE_TRESHOLD ]; } | ||||
|   function CPU1_OVERHEAT () { [ $CPU1_TEMPERATURE -gt $CPU_TEMPERATURE_THRESHOLD ]; } | ||||
|   if $IS_CPU2_TEMPERATURE_SENSOR_PRESENT | ||||
|   then | ||||
|     function CPU2_OVERHEAT () { [ $CPU2_TEMPERATURE -gt $CPU_TEMPERATURE_TRESHOLD ]; } | ||||
|     function CPU2_OVERHEAT () { [ $CPU2_TEMPERATURE -gt $CPU_TEMPERATURE_THRESHOLD ]; } | ||||
|   fi | ||||
|  | ||||
|   # Initialize a variable to store the comments displayed when the fan control profile changed | ||||
| @@ -209,7 +209,7 @@ while true; do | ||||
|     if $IS_DELL_FAN_CONTROL_PROFILE_APPLIED | ||||
|     then | ||||
|       IS_DELL_FAN_CONTROL_PROFILE_APPLIED=false | ||||
|       COMMENT="CPU temperature decreased and is now OK (<= $CPU_TEMPERATURE_TRESHOLD°C), user's fan control profile applied." | ||||
|       COMMENT="CPU temperature decreased and is now OK (<= $CPU_TEMPERATURE_THRESHOLD°C), user's fan control profile applied." | ||||
|     fi | ||||
|   fi | ||||
|  | ||||
|   | ||||
| @@ -16,7 +16,7 @@ ENV IDRAC_HOST local | ||||
| #ENV IDRAC_USERNAME root | ||||
| #ENV IDRAC_PASSWORD calvin | ||||
| ENV FAN_SPEED 5 | ||||
| ENV CPU_TEMPERATURE_TRESHOLD 50 | ||||
| ENV CPU_TEMPERATURE_THRESHOLD 50 | ||||
| ENV CHECK_INTERVAL 60 | ||||
| ENV DISABLE_THIRD_PARTY_PCIE_CARD_DELL_DEFAULT_COOLING_RESPONSE false | ||||
|  | ||||
|   | ||||
							
								
								
									
										12
									
								
								README.md
									
									
									
									
									
								
							
							
						
						
									
										12
									
								
								README.md
									
									
									
									
									
								
							| @@ -66,7 +66,7 @@ docker run -d \ | ||||
|   --restart=unless-stopped \ | ||||
|   -e IDRAC_HOST=local \ | ||||
|   -e FAN_SPEED=<decimal or hexadecimal fan speed> \ | ||||
|   -e CPU_TEMPERATURE_TRESHOLD=<decimal temperature treshold> \ | ||||
|   -e CPU_TEMPERATURE_THRESHOLD=<decimal temperature threshold> \ | ||||
|   -e CHECK_INTERVAL=<seconds between each check> \ | ||||
|   -e DISABLE_THIRD_PARTY_PCIE_CARD_DELL_DEFAULT_COOLING_RESPONSE=<true or false> \ | ||||
|   --device=/dev/ipmi0:/dev/ipmi0:rw \ | ||||
| @@ -83,7 +83,7 @@ docker run -d \ | ||||
|   -e IDRAC_USERNAME=<iDRAC username> \ | ||||
|   -e IDRAC_PASSWORD=<iDRAC password> \ | ||||
|   -e FAN_SPEED=<decimal or hexadecimal fan speed> \ | ||||
|   -e CPU_TEMPERATURE_TRESHOLD=<decimal temperature treshold> \ | ||||
|   -e CPU_TEMPERATURE_THRESHOLD=<decimal temperature threshold> \ | ||||
|   -e CHECK_INTERVAL=<seconds between each check> \ | ||||
|   -e DISABLE_THIRD_PARTY_PCIE_CARD_DELL_DEFAULT_COOLING_RESPONSE=<true or false> \ | ||||
|   tigerblue77/dell_idrac_fan_controller:latest | ||||
| @@ -104,7 +104,7 @@ services: | ||||
|     environment: | ||||
|       - IDRAC_HOST=local | ||||
|       - FAN_SPEED=<decimal or hexadecimal fan speed> | ||||
|       - CPU_TEMPERATURE_TRESHOLD=<decimal temperature treshold> | ||||
|       - CPU_TEMPERATURE_THRESHOLD=<decimal temperature threshold> | ||||
|       - CHECK_INTERVAL=<seconds between each check> | ||||
|       - DISABLE_THIRD_PARTY_PCIE_CARD_DELL_DEFAULT_COOLING_RESPONSE=<true or false> | ||||
|     devices: | ||||
| @@ -126,7 +126,7 @@ services: | ||||
|       - IDRAC_USERNAME=<iDRAC username> | ||||
|       - IDRAC_PASSWORD=<iDRAC password> | ||||
|       - FAN_SPEED=<decimal or hexadecimal fan speed> | ||||
|       - CPU_TEMPERATURE_TRESHOLD=<decimal temperature treshold> | ||||
|       - CPU_TEMPERATURE_THRESHOLD=<decimal temperature threshold> | ||||
|       - CHECK_INTERVAL=<seconds between each check> | ||||
|       - DISABLE_THIRD_PARTY_PCIE_CARD_DELL_DEFAULT_COOLING_RESPONSE=<true or false> | ||||
| ``` | ||||
| @@ -142,7 +142,7 @@ All parameters are optional as they have default values (including default iDRAC | ||||
| - `IDRAC_USERNAME` parameter is only necessary if you're adressing a distant iDRAC. **Default** value is "root". | ||||
| - `IDRAC_PASSWORD` parameter is only necessary if you're adressing a distant iDRAC. **Default** value is "calvin". | ||||
| - `FAN_SPEED` parameter can be set as a decimal (from 0 to 100%) or hexadecimaladecimal value (from 0x00 to 0x64) you want to set the fans to. **Default** value is 5(%). | ||||
| - `CPU_TEMPERATURE_TRESHOLD` parameter is the T°junction (junction temperature) threshold beyond which the Dell fan mode defined in your BIOS will become active again (to protect the server hardware against overheat). **Default** value is 50(°C). | ||||
| - `CPU_TEMPERATURE_THRESHOLD` parameter is the T°junction (junction temperature) threshold beyond which the Dell fan mode defined in your BIOS will become active again (to protect the server hardware against overheat). **Default** value is 50(°C). | ||||
| - `CHECK_INTERVAL` parameter is the time (in seconds) between each temperature check and potential profile change. **Default** value is 60(s). | ||||
| - `DISABLE_THIRD_PARTY_PCIE_CARD_DELL_DEFAULT_COOLING_RESPONSE` parameter is a boolean that allows to disable third-party PCIe card Dell default cooling response. **Default** value is false. | ||||
|  | ||||
| @@ -152,7 +152,7 @@ All parameters are optional as they have default values (including default iDRAC | ||||
| ## Troubleshooting | ||||
|  | ||||
| If your server frequently switches back to the default Dell fan mode: | ||||
| 1. Check `Tcase` (case temperature) of your CPU on Intel Ark website and then set `CPU_TEMPERATURE_TRESHOLD` to a slightly lower value. Example with my CPUs ([Intel Xeon E5-2630L v2](https://www.intel.com/content/www/us/en/products/sku/75791/intel-xeon-processor-e52630l-v2-15m-cache-2-40-ghz/specifications.html)) : Tcase = 63°C, I set `CPU_TEMPERATURE_TRESHOLD` to 60(°C). | ||||
| 1. Check `Tcase` (case temperature) of your CPU on Intel Ark website and then set `CPU_TEMPERATURE_THRESHOLD` to a slightly lower value. Example with my CPUs ([Intel Xeon E5-2630L v2](https://www.intel.com/content/www/us/en/products/sku/75791/intel-xeon-processor-e52630l-v2-15m-cache-2-40-ghz/specifications.html)) : Tcase = 63°C, I set `CPU_TEMPERATURE_THRESHOLD` to 60(°C). | ||||
| 2. If it's already good, adapt your `FAN_SPEED` value to increase the airflow and thus further decrease the temperature of your CPU(s) | ||||
| 3. If neither increasing the fan speed nor increasing the threshold solves your problem, then it may be time to replace your thermal paste | ||||
|  | ||||
|   | ||||