mirror of
https://github.com/tigerblue77/Dell_iDRAC_fan_controller_Docker.git
synced 2025-10-23 04:51:57 +00:00
Renamed variable
This commit is contained in:
@@ -21,7 +21,7 @@ HEALTHCHECK --interval=30s --timeout=30s --start-period=5s --retries=3 CMD [ "/a
|
||||
ENV IDRAC_HOST local
|
||||
# ENV IDRAC_USERNAME root
|
||||
# ENV IDRAC_PASSWORD calvin
|
||||
ENV DELL_14_GEN false
|
||||
ENV DELL_POWEREDGE_GEN_14_OR_NEWER false
|
||||
ENV FAN_SPEED 5
|
||||
ENV CPU_TEMPERATURE_THRESHOLD 50
|
||||
ENV CHECK_INTERVAL 60
|
||||
|
@@ -162,7 +162,7 @@ All parameters are optional as they have default values (including default iDRAC
|
||||
- `CHECK_INTERVAL` parameter is the time (in seconds) between each temperature check and potential profile change. **Default** value is 60(s).
|
||||
- `DISABLE_THIRD_PARTY_PCIE_CARD_DELL_DEFAULT_COOLING_RESPONSE` parameter is a boolean that allows to disable third-party PCIe card Dell default cooling response. **Default** value is false.
|
||||
- `KEEP_THIRD_PARTY_PCIE_CARD_COOLING_RESPONSE_STATE_ON_EXIT` parameter is a boolean that allows to keep the third-party PCIe card Dell default cooling response state upon exit. **Default** value is false, so that it resets the third-party PCIe card Dell default cooling response to Dell default.
|
||||
- `DELL_14_GEN` parameter that disabled 3rd party PCI calls and outputs CPU temperatures correctly for 14th Gen Dell servers, ex Dell r640, 740 series. Must have idrac 3.30.30.30 or older. **Default** value is false.
|
||||
- `DELL_POWEREDGE_GEN_14_OR_NEWER` parameter that disabled 3rd party PCI calls and outputs CPU temperatures correctly for 14th Gen Dell servers, ex Dell r640, 740 series. Must have idrac 3.30.30.30 or older. **Default** value is false.
|
||||
|
||||
<p align="right">(<a href="#top">back to top</a>)</p>
|
||||
|
||||
|
@@ -38,7 +38,7 @@ function retrieve_temperatures () {
|
||||
|
||||
# Parse CPU data
|
||||
local CPU_DATA=$(echo "$DATA" | grep "3\." | grep -Po '\d{2}')
|
||||
if $DELL_14_GEN
|
||||
if $DELL_POWEREDGE_GEN_14_OR_NEWER
|
||||
then
|
||||
# 14 Gen server or newer
|
||||
CPU1_TEMPERATURE=$(echo $CPU_DATA | awk '{print $2;}')
|
||||
@@ -48,7 +48,7 @@ function retrieve_temperatures () {
|
||||
fi
|
||||
if $IS_CPU2_TEMPERATURE_SENSOR_PRESENT
|
||||
then
|
||||
if $DELL_14_GEN
|
||||
if $DELL_POWEREDGE_GEN_14_OR_NEWER
|
||||
then
|
||||
# 14 Gen server or newer
|
||||
CPU2_TEMPERATURE=$(echo $CPU_DATA | awk '{print $4;}')
|
||||
@@ -74,7 +74,7 @@ function retrieve_temperatures () {
|
||||
|
||||
function enable_third_party_PCIe_card_Dell_default_cooling_response () {
|
||||
# We could check the current cooling response before applying but it's not very useful so let's skip the test and apply directly
|
||||
if ! $DELL_14_GEN
|
||||
if ! $DELL_POWEREDGE_GEN_14_OR_NEWER
|
||||
then
|
||||
# 13 Gen server or older
|
||||
ipmitool -I $IDRAC_LOGIN_STRING raw 0x30 0xce 0x00 0x16 0x05 0x00 0x00 0x00 0x05 0x00 0x00 0x00 0x00 > /dev/null
|
||||
@@ -83,7 +83,7 @@ function enable_third_party_PCIe_card_Dell_default_cooling_response () {
|
||||
|
||||
function disable_third_party_PCIe_card_Dell_default_cooling_response () {
|
||||
# We could check the current cooling response before applying but it's not very useful so let's skip the test and apply directly
|
||||
if ! $DELL_14_GEN
|
||||
if ! $DELL_POWEREDGE_GEN_14_OR_NEWER
|
||||
then
|
||||
# 13 Gen server or older
|
||||
ipmitool -I $IDRAC_LOGIN_STRING raw 0x30 0xce 0x00 0x16 0x05 0x00 0x00 0x00 0x05 0x00 0x01 0x00 0x00 > /dev/null
|
||||
|
Reference in New Issue