@@ -0,0 +1,577 @@
|
||||
-- *****************************************************************
|
||||
-- CISCO-MGX82XX-DSX3-BERT MIB: Bit Error Rate Testing MIB for DSX3
|
||||
-- interfaces in MGX82xx series.
|
||||
--
|
||||
-- January 2003, Subra Hegde
|
||||
--
|
||||
-- Copyright (c) 2003 by cisco Systems, Inc.
|
||||
-- All rights reserved.
|
||||
-- *****************************************************************
|
||||
|
||||
CISCO-MGX82XX-DSX3-BERT-MIB DEFINITIONS ::= BEGIN
|
||||
IMPORTS
|
||||
MODULE-IDENTITY,
|
||||
OBJECT-TYPE,
|
||||
Integer32 FROM SNMPv2-SMI
|
||||
MODULE-COMPLIANCE,
|
||||
OBJECT-GROUP FROM SNMPv2-CONF
|
||||
DisplayString FROM SNMPv2-TC
|
||||
axisDiagnostics FROM BASIS-MIB
|
||||
ciscoWan FROM CISCOWAN-SMI;
|
||||
|
||||
ciscoMgx82xxDsx3BertMIB MODULE-IDENTITY
|
||||
LAST-UPDATED "200301020000Z"
|
||||
ORGANIZATION "Cisco Systems, Inc."
|
||||
CONTACT-INFO
|
||||
" Cisco Systems
|
||||
Customer Service
|
||||
|
||||
Postal: 170 W Tasman Drive
|
||||
San Jose, CA 95134
|
||||
USA
|
||||
|
||||
Tel: +1 800 553-NETS
|
||||
|
||||
E-mail: cs-wanatm@cisco.com"
|
||||
DESCRIPTION
|
||||
"The MIB Module for BERT (Bit Error Rate Testing)
|
||||
on ds3 interfaces in some of the cards (Service Modules)
|
||||
in MGX products.
|
||||
|
||||
This MIB is applicable for following T3/E3 Service Modules:
|
||||
FRSM-2T3E3 : Frame Relay Service Module.
|
||||
CESM-T3E3 : Circuit Emulation Service Module."
|
||||
|
||||
REVISION "200301020000Z"
|
||||
DESCRIPTION
|
||||
"Initial version of the MIB.
|
||||
|
||||
The content of this MIB was originally available
|
||||
in CISCO-WAN-AXIPOP-MIB defined using SMIv1.
|
||||
The applicable objects from CISCO-WAN-AXIPOP-MIB
|
||||
are defined using SMIv2 in this MIB. Also the
|
||||
descriptions of some of the objects have been
|
||||
modified."
|
||||
::= { ciscoWan 39 }
|
||||
|
||||
dsx3bert OBJECT IDENTIFIER ::= { axisDiagnostics 2 }
|
||||
|
||||
dsx3bertControl OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
noAction (0),
|
||||
acquireBert (1),
|
||||
releaseBert (2),
|
||||
cnfBert (3),
|
||||
startBert (4),
|
||||
modBert (5),
|
||||
delBert (6)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object controls all the SET operations on this MIB group.
|
||||
noAction : No action is taken. This value can not be written
|
||||
This object contains value noAction(0)
|
||||
just after setting it to delBert(6).
|
||||
acquireBert : Acquire BERT resources.
|
||||
cnfBert : Configure the required BERT test.
|
||||
startBert : The configured test has to be started.
|
||||
modBert : Modify parameters for the ongoing BERT test.
|
||||
delBert : Running BERT test has to be stopped.
|
||||
This value is write-only. This value is
|
||||
never returned for a SNMP Get request.
|
||||
|
||||
For Performing BERT : Following sequence need to be done.
|
||||
* acquire BERT by setting this object to acquireBert(1).
|
||||
* configure BERT by setting this object to cnfBert(3)
|
||||
* Start BERT by setting this object to startBert(4).
|
||||
* Modify BERT parameters by setting this object to modBert(5)."
|
||||
DEFVAL { noAction }
|
||||
::= { dsx3bert 1 }
|
||||
|
||||
dsx3bertResourceStatus OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
free (1),
|
||||
inUse (2)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"All of bert resources can be used by only one user at a time.
|
||||
This object provides the status of the resources."
|
||||
DEFVAL { free }
|
||||
::= { dsx3bert 2 }
|
||||
|
||||
dsx3bertOwner OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This refers to the user who owns the BERT resources.
|
||||
If the user is a CLI user, then this is username.
|
||||
If it is SNMP Manager, then this would be the ASCII
|
||||
form of the IP address."
|
||||
::= { dsx3bert 3 }
|
||||
|
||||
dsx3bertUserId OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This identifies the user who wants to do a SET operation
|
||||
on this group. This will be compared against bertOwner
|
||||
and access will be given only if it matches. Hence, for
|
||||
every SET request, this object should have a valid value.
|
||||
If the user is a CLI user, then this is login username.
|
||||
|
||||
If it is SNMP Manager, then this would be the ASCII
|
||||
form of the IP address."
|
||||
::= { dsx3bert 4 }
|
||||
|
||||
dsx3bertStatus OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
inactive (1),
|
||||
bertInSync (2),
|
||||
bertOutOfSync (3),
|
||||
farEndInLoop (4),
|
||||
metallicInLoop (5),
|
||||
bertFailed (6)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object provides the status of BERT in the shelf.
|
||||
|
||||
The possible values are :
|
||||
inactive (1) : BERT not in progress
|
||||
bertInSync (2) : BERT is activated and receive side is
|
||||
synchronized with the incoming sequence
|
||||
of patterns.
|
||||
bertOutOfSync (3) : BERT is activated and receive is out of
|
||||
synchronization with the incoming sequence
|
||||
of patterns.
|
||||
farEndInLoop (4) : Far End is in loop back.
|
||||
metallicInLoop(5) : Local Loopback set.
|
||||
bertFailed (6) : BERT Failed.
|
||||
|
||||
farEndInLoop(4) is not applicable for CESM-T3E3
|
||||
and FRSM-2T3E3."
|
||||
DEFVAL { inactive }
|
||||
::= { dsx3bert 5 }
|
||||
|
||||
dsx3bertTestMedium OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
port (1),
|
||||
line (2)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Specifies whether the BERT is to be tested on a port or an
|
||||
entire T3/E3 line.
|
||||
For a BERT test, this object must be set.
|
||||
For CESM-T3E3 and FRSM-@T3E3, this object must be set
|
||||
to line(2)."
|
||||
::= { dsx3bert 6 }
|
||||
|
||||
dsx3bertPort OBJECT-TYPE
|
||||
SYNTAX Integer32 (1..2147483647)
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object specifies the port number for BERT.
|
||||
Port level bert is not supported in CESM-T3E3 and
|
||||
FRSM-2T3E3. So for these cards, the value must be always 1. "
|
||||
::= { dsx3bert 7 }
|
||||
|
||||
dsx3bertLine OBJECT-TYPE
|
||||
SYNTAX Integer32 (1..2147483647)
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object specifies the line number for BERT.
|
||||
If the dsx3bertTestMedium is set to port(1),
|
||||
this represents the line to which the port
|
||||
(dsx3bertPort) belongs.
|
||||
The value supported depends upon the type of
|
||||
card (service module)."
|
||||
::= { dsx3bert 8 }
|
||||
|
||||
dsx3bertMode OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
bertPatternTest (1),
|
||||
loopback (2)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object specifies the mode, the BERT module is to be
|
||||
configured for.
|
||||
The value loopback(2) is not supported in CESM-T3E3 and FRSM-2T3E3 . "
|
||||
::= { dsx3bert 9 }
|
||||
|
||||
dsx3bertPattern OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
allOnes (1),
|
||||
allZeros (2),
|
||||
alternateOneZero (3),
|
||||
doubleOneZero (4),
|
||||
threeInTwentyFour (5),
|
||||
oneInSixteen (6),
|
||||
oneInEight (7),
|
||||
oneInFour (8),
|
||||
sfLoopUp (9),
|
||||
sfLoopDown (10),
|
||||
threeBit (11),
|
||||
fourBit (12),
|
||||
fiveBit (13),
|
||||
sixBit (14),
|
||||
sevenBit (15),
|
||||
fracT1LoopUp (16),
|
||||
fracT1LoopDown (17),
|
||||
nineBit (18),
|
||||
tenBit (19),
|
||||
elevenBit (20),
|
||||
fifteenBit (21),
|
||||
seventeenBit (22),
|
||||
eighteenBit (23),
|
||||
twentyBit (24),
|
||||
twentyBitQRSS (25),
|
||||
twentyOneBit (26),
|
||||
twentyTwoBit (27),
|
||||
twentyThreeBit (28),
|
||||
twentyFiveBit (29),
|
||||
twentyEightBit (30),
|
||||
twentyNineBit (31),
|
||||
thirtyOneBit (32),
|
||||
thirtyTwo (33)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable determines BERT pattern to be transmitted
|
||||
on the interface identified by dsx3bertLine or dsx3bertPort.
|
||||
|
||||
Bit error measurements are widely used to assess the
|
||||
performance of a digital transmission equipment. Precise
|
||||
error measurement requires that the bit pattern transmitted
|
||||
is known before hand. During BER testing a known pattern is
|
||||
transmitted on a interface. The pattern received on the
|
||||
receive side is checked for bit errors. In order to measure
|
||||
the performance of digital line under real condition
|
||||
this patterns should also simulate real traffic as closely
|
||||
as possible. There are two categories of test patterns that
|
||||
can be generated by a BERT equipment: repetitive and
|
||||
pseudo-random. The former test patterns are zeroes or ones
|
||||
or alternating zeroes and ones; the latter patterns are
|
||||
exponential numbers and conform to CCITT/ITU O.151, O.153.
|
||||
|
||||
There are different patterns for different interface speeds.
|
||||
This object allows the user to configure this BERT patterns.
|
||||
|
||||
The supported values are :
|
||||
|
||||
Repetitive Patterns
|
||||
|
||||
allOnes(1): All Ones(Continuous Marks). This is repeating
|
||||
pattern of ones(...1111...). This provides
|
||||
testing of maximum power level requirements.
|
||||
The all one pattern test causes the repeater
|
||||
to consume the maximum amount of power.
|
||||
If there is insufficient DC span power then the
|
||||
repeater may begin to fail.
|
||||
Typically this pattern is used for a simple
|
||||
continuity check. It may also be used to detect
|
||||
the presence of unwanted loop in the network.
|
||||
|
||||
allZeros(2): All Zeroes(Continuous spaces). This is
|
||||
repeating pattern of zeros(...000...).
|
||||
The use of this pattern is to test and verify
|
||||
that the ones density policing mechanism is
|
||||
functioning properly. This pattern must be
|
||||
used in circuits optioned for B8ZS.
|
||||
|
||||
alternateOneZero(3): Alternate one/zero pattern(..1010..).
|
||||
This pattern produces a 50% ones density. It is
|
||||
used to stress the repeater's DC power
|
||||
consumption.
|
||||
|
||||
doubleOneZero(4): Double alternate one/zero(..10101010..).
|
||||
|
||||
threeInTwentyFour(5): This is a 24 bit pattern which
|
||||
contains 3 ones. The largest string of consecutive
|
||||
zeros is fifteen.
|
||||
This pattern is used primarily to test timing(clock)
|
||||
recovery and may be used framed or unframed for that
|
||||
purpose. This pattern covers both the minimum ones
|
||||
density and the maximum number of consecutive zeros.
|
||||
|
||||
oneInSixteen(6): N repetitive pattern, 1 in 16.
|
||||
|
||||
oneInEight(7): This is an eight bit pattern which contains
|
||||
single one.
|
||||
This pattern is used primarily to test timing(clock)
|
||||
recovery and may be used framed or unframed for that
|
||||
purpose.
|
||||
This pattern is used to verify frame synchronization
|
||||
by providing the minimum acceptable pulse density.
|
||||
|
||||
|
||||
oneInFour(8): This pattern is standard loop up remote code.
|
||||
Typically it is used when the loop up remote test
|
||||
fails to place the remote system into loopback.
|
||||
|
||||
sfLoopUp (9): D4/SF Loopback activate/up
|
||||
Valid only for T1 line.
|
||||
sfLoopDown(10): D4/SF Loopback deactivate/down
|
||||
Valid only for T1 line.
|
||||
threeBit (11): Repetitive patterns of 3 bits in length.
|
||||
fourBit (12): Repetitive patterns of 4 bits in length.
|
||||
fiveBit (13): Repetitive patterns of 5 bits in length.
|
||||
sixBit (14): Repetitive patterns of 6 bits in length.
|
||||
sevenBit (15): Repetitive patterns of 7 bits in length.
|
||||
fracT1LoopUp(16): Fractional T1 Loopback activate/up.
|
||||
fracT1LoopDown(17): Fractional T1 Loopback deactivate/down.
|
||||
|
||||
nineBit (18): Repetitive patterns of 9 bits in length.
|
||||
tenBit (19): Repetitive patterns of 10 bits in length.
|
||||
elevenBit (20): Repetitive patterns of 11 bits in length.
|
||||
fifteenBit (21): Repetitive patterns of 15 bits in length.
|
||||
seventeenBit (22): Repetitive patterns of 17 bits in length.
|
||||
eighteenBit (23): Repetitive patterns of 18 bits in length.
|
||||
twentyBit (24): Repetitive patterns of 20 bits in length.
|
||||
twentyBitQRSS(25): 20 bits of Quasi Random Signal Source.
|
||||
twentyOneBit (26): Repetitive patterns of 21 bits in length.
|
||||
twentyTwoBit (27): Repetitive patterns of 22 bits in length.
|
||||
twentyThreeBit (28): Repetitive patterns of 23 bits in length.
|
||||
twentyFiveBit (29): Repetitive patterns of 25 bits in length.
|
||||
twentyEightBit (30): Repetitive patterns of 28 bits in length.
|
||||
twentyNineBit (31): Repetitive patterns of 29 bits in length.
|
||||
thirtyOneBit (32): Repetitive patterns of 32 bits in length.
|
||||
thirtyTwo (33): Repetitive patterns of 33 bits in length.
|
||||
"
|
||||
REFERENCE
|
||||
"CCITT/ITU O.150, O.151, O.152, O.153, O.161 Standards."
|
||||
::= { dsx3bert 10 }
|
||||
|
||||
dsx3bertLoopback OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
farEndLoopback (1),
|
||||
metallicLoopback (2)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object specifies the type of loopback to be
|
||||
established/de-established.
|
||||
The value farEndLoopback(1) is not supported in
|
||||
CESM-T3E3 and FRSM-2T3E3, where the default value for
|
||||
this object shall be 2."
|
||||
::= { dsx3bert 11 }
|
||||
|
||||
dsx3bertStartTime OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE (0 | 8))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object contains the time at which
|
||||
BERT started. The syntax is hh:mm:ss.
|
||||
The time zone is as configured in the shelf.
|
||||
|
||||
This object contains zero length string for following
|
||||
values of dsx3bertControl:
|
||||
noAction (0),
|
||||
acquireBert (1),
|
||||
releaseBert (2),
|
||||
cnfBert (3)."
|
||||
::= { dsx3bert 12 }
|
||||
|
||||
dsx3bertStartDate OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE (0 | 8))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object contains the date on which
|
||||
BERT started. The syntax is yy/mm/dd.
|
||||
|
||||
This object contains zero length string for following
|
||||
values of dsx3bertControl:
|
||||
noAction (0),
|
||||
acquireBert (1),
|
||||
releaseBert (2),
|
||||
cnfBert (3)."
|
||||
::= { dsx3bert 13 }
|
||||
|
||||
dsx3bertBitCountUpper OBJECT-TYPE
|
||||
SYNTAX Integer32(0..2147483647)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This number of bits transmitted is represented in an encoded
|
||||
form as a 64-bit counter. This object gives the upper 31 bits
|
||||
of the 64 bit counter. The 32nd bit is not available."
|
||||
::= { dsx3bert 14 }
|
||||
|
||||
dsx3bertBitCountLower OBJECT-TYPE
|
||||
SYNTAX Integer32(0..2147483647)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This number of bits transmitted is represented in an encoded
|
||||
form as a 64-bit counter. This object gives the lower 31 bits
|
||||
of the 64 bit counter. The 32nd bit is not available."
|
||||
::= { dsx3bert 15 }
|
||||
|
||||
dsx3bertBitErrorCountUpper OBJECT-TYPE
|
||||
SYNTAX Integer32(0..2147483647)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This number of bits received in error is represented in
|
||||
an encoded form as a 64-bit counter. This object gives the
|
||||
upper 31 bits of the 64 bit counter. The 32nd bit is not
|
||||
available."
|
||||
::= { dsx3bert 16 }
|
||||
|
||||
dsx3bertBitErrorCountLower OBJECT-TYPE
|
||||
SYNTAX Integer32(0..2147483647)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This number of bits received in error is represented in
|
||||
an encoded form as a 64-bit counter. This object gives the
|
||||
lower 31 bits of the 64 bit counter. The 32nd bit is not
|
||||
available."
|
||||
::= { dsx3bert 17 }
|
||||
|
||||
dsx3bertErrorInsertionRate OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
errorInsertionDisabled (1),
|
||||
oneInTen (2),
|
||||
oneInTenPowerTwo (3),
|
||||
oneInTenPowerThree (4),
|
||||
oneInTenPowerFour (5),
|
||||
oneInTenPowerFive (6),
|
||||
oneInTenPowerSix (7),
|
||||
oneInTenPowerSeven (8)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object is used for injecting continuous errors into
|
||||
transmitted BERT pattern. The errors are inserted in a BERT
|
||||
pattern sent, in order to do sanity check on receive interface
|
||||
in the event that no bit errors are detected. Injecting errors
|
||||
allows users to stress communication links and to check the
|
||||
functionality of error monitoring equipment along the path.
|
||||
Once set to send continuous errors, errors will be inserted
|
||||
at the configured rate until set to errorInsertionDisabled(1).
|
||||
|
||||
The possible values are :
|
||||
|
||||
errorInsertionDisabled(1) : no bit errors are inserted.
|
||||
|
||||
oneInTen(2) : insert bit errors at the rate of 1 bit
|
||||
error per 10 bits (10^-1) transmitted.
|
||||
|
||||
oneInTenPowerTwo(3) : insert bit errors at the rate of 1 bit
|
||||
error per 100 bits (10^-2) transmitted.
|
||||
|
||||
oneInTenPowerThree(4): insert bit errors at the rate of 1 bit
|
||||
error per 1000 bits (10^-3) transmitted.
|
||||
|
||||
oneInTenPowerFour(5): insert bit errors at the rate of 1 bit
|
||||
error per 10000 (10^-4) bits transmitted.
|
||||
|
||||
oneInTenPowerFive(6): insert bit errors at the rate of 1 bit
|
||||
error per 100000 bits (10^-5) transmitted.
|
||||
|
||||
oneInTenPowerSix(7) : insert bit errors at the rate of 1 bit
|
||||
error per 1000000 bits (10^-6) transmitted.
|
||||
|
||||
oneInTenPowerSeven(8): insert bit errors at the rate of 1 bit
|
||||
error per 10,000,000 (10^-7)bits transmitted. "
|
||||
::= { dsx3bert 18 }
|
||||
|
||||
dsx3bertErrorInjectCount OBJECT-TYPE
|
||||
SYNTAX Integer32(0..2147483647)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This shows the number of times error was injected."
|
||||
::= { dsx3bert 19 }
|
||||
|
||||
dsx3bertCleanupAction OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
noAction (1),
|
||||
smCleanup (2),
|
||||
metallicLoopdown (3)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"When the BERT has to be stopped or aborted (due to card state
|
||||
changes), this object would give the exact action to take.
|
||||
The bert related changes to the card, then, can be cleaned up.
|
||||
|
||||
The value metallicLoopdown(3) is not applicable for
|
||||
CESM-T3E3 and FRSM-2T3E3.
|
||||
|
||||
When its value is metallicLoopdown(3), it implies
|
||||
smCleanup plus the corresponding Loopdown."
|
||||
DEFVAL { noAction }
|
||||
::= { dsx3bert 20 }
|
||||
|
||||
-- conformance information
|
||||
|
||||
cmDsx3BertMIBConformance OBJECT IDENTIFIER ::= { ciscoMgx82xxDsx3BertMIB 2 }
|
||||
|
||||
cmDsx3BertMIBGroups OBJECT IDENTIFIER ::=
|
||||
{ cmDsx3BertMIBConformance 1 }
|
||||
|
||||
cmDsx3BertMIBCompliances OBJECT IDENTIFIER ::=
|
||||
{ cmDsx3BertMIBConformance 2 }
|
||||
|
||||
-- compliance statements
|
||||
|
||||
cmDsx3BertCompliance MODULE-COMPLIANCE
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The compliance statement for objects related
|
||||
to Bert MIB."
|
||||
MODULE -- this module
|
||||
MANDATORY-GROUPS {
|
||||
cmDsx3BertConfGroup
|
||||
}
|
||||
::= { cmDsx3BertMIBCompliances 1 }
|
||||
|
||||
cmDsx3BertConfGroup OBJECT-GROUP
|
||||
OBJECTS {
|
||||
dsx3bertControl,
|
||||
dsx3bertResourceStatus,
|
||||
dsx3bertOwner,
|
||||
dsx3bertUserId,
|
||||
dsx3bertStatus,
|
||||
dsx3bertTestMedium,
|
||||
dsx3bertPort,
|
||||
dsx3bertLine,
|
||||
dsx3bertMode,
|
||||
dsx3bertPattern,
|
||||
dsx3bertLoopback,
|
||||
dsx3bertStartTime,
|
||||
dsx3bertStartDate,
|
||||
dsx3bertBitCountUpper,
|
||||
dsx3bertBitCountLower,
|
||||
dsx3bertBitErrorCountUpper,
|
||||
dsx3bertBitErrorCountLower,
|
||||
dsx3bertErrorInsertionRate,
|
||||
dsx3bertErrorInjectCount,
|
||||
dsx3bertCleanupAction
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The collection of objects which are used for
|
||||
configuring/running BERT on DSX3 interfaces."
|
||||
::= { cmDsx3BertMIBGroups 1 }
|
||||
|
||||