Files
openbts/Transceiver52M
Thomas Tsou 0e0c81de63 Transceiver52M: Set resampling option automatically based on device
Remove the built time resampling selection and link both options.
Move the normal push/pullBuffer() calls back to the base class and
overload them in the inherited resampling class.

USRP2/N2xx devices are the only devices that require resampling so
return that resampling is necessary on the device open(), which is
the point at which the device type will be known.

The GSM transceiver only operates at a whole number multiple of
the GSM rate and doesn't care about the actual device rate and
if resampling is used. Therefore GSM specific portion of the
transceiver should only need to submit the samples-per-symbol
value to the device interface.

Then, the device should be able to determine the appropriate
sample rate (400 ksps or 270.833 ksps) and if resampling is
appropriate.

Signed-off-by: Thomas Tsou <tom@tsou.cc>

git-svn-id: http://wush.net/svn/range/software/public/openbts/trunk@6723 19bc5d8c-e614-43d4-8b26-e1612bc8e597
2013-10-17 06:17:35 +00:00
..
2012-11-23 08:37:32 +00:00
2013-08-14 00:52:14 +00:00

The Transceiver

The transceiver consists of three modules:
   --- transceiver
   --- radioInterface
   --- USRPDevice

The USRPDevice module is basically a driver that reads/writes
packets to a USRP with two RFX900 daughterboards, board 
A is the Tx chain and board B is the Rx chain.  

The radioInterface module is basically an interface b/w the
transceiver and the USRP.   It operates the basestation clock
based upon the sample count of received USRP samples.  Packets 
from the USRP are queued and segmented into GSM bursts that are
passed up to the transceiver; bursts from the transceiver are
passed down to the USRP. 

The transceiver basically operates "layer 0" of the GSM stack,
performing the modulation, detection, and demodulation of GSM 
bursts.  It communicates with the GSM stack via three UDP sockets,
one socket for data, one for control messages, and one socket to
pass clocking information.  The transceiver contains a priority
queue to sort to-be-transmitted bursts, and a filler table to fill
in timeslots that do not have bursts in the priority queue.  The
transceiver tries to stay ahead of the basestation clock, adapting 
its latency when underruns are reported by the radioInterface/USRP.
Received bursts (from the radioInterface) pass through a simple 
energy detector, a RACH or midamble correlator, and a DFE-based demodulator.

NOTE: There's a SWLOOPBACK #define statement, where the USRP is replaced
with a memory buffer.  In this mode, data written to the USRP is actually stored 
in a buffer, and read commands to the USRP simply pull data from this buffer.
This was very useful in early testing, and still may be useful in testing basic
Transceiver and radioInterface functionality.