mirror of
https://gitea.osmocom.org/cellular-infrastructure/osmo-upf.git
synced 2025-11-02 13:03:35 +00:00
manual: explain new netinst cfg
Related: SYS#6192 Change-Id: I1d636b8a6ae7628b4369734a45e60f2eaf437dce
This commit is contained in:
56
doc/manuals/chapters/netinst.adoc
Normal file
56
doc/manuals/chapters/netinst.adoc
Normal file
@@ -0,0 +1,56 @@
|
||||
== Local GTP Addresses / Network Instance
|
||||
|
||||
PFCP features optional Network Instance IEs, in which the CPF may tell the UPF which local network interface to use for
|
||||
a PDR and/or a FAR.
|
||||
|
||||
NOTE:: osmo-upf only evaluates the Network Instances configured in PDRs. Since osmo-upf always pairs a PDR+FAR with
|
||||
another PDR+FAR in reverse direction, each side's PDR is sufficient.
|
||||
|
||||
Network Instance IEs affect both the tunend and the tunmap use cases, as well as which local IP address is returned
|
||||
in the PFCP response
|
||||
|
||||
1. Look up Network Instance name in the osmo-upf.cfg `netinst` section, to obtain a local IP address.
|
||||
2. Depending on use case:
|
||||
- tunend: create the tunnel on a GTP device matching the local IP address, see <<gtp_module>>.
|
||||
- tunmap: use the local IP address in the netfilter ruleset, see <<nftables>>.
|
||||
3. Usually, return the chosen local IP address in the F-TEID IE of the Created PDR IE in the PFCP response.
|
||||
|
||||
Network Instance configuration consists of {name, IP address} pairs.
|
||||
|
||||
NOTE:: As soon as a `netinst` configuration is nonempty, receiving an undefined Network Instance name results in a PFCP
|
||||
Reject response, and a log message on cateogry `session`, level `NOTICE`. To make the PFCP return success, add the
|
||||
failing name to the `netinst` config.
|
||||
|
||||
=== netinst for tunend
|
||||
|
||||
The following configuration sets up two GTP devices for tunend, expecting Network Instance names `access1` or `access2`:
|
||||
|
||||
----
|
||||
tunend
|
||||
dev create apn1 10.0.0.1
|
||||
dev create apn2 10.0.0.2
|
||||
netinst
|
||||
add access1 10.0.0.1
|
||||
add access2 10.0.0.2
|
||||
----
|
||||
|
||||
For example, if a Create PDR IE indicates Network Instance = `access1`, a GTP tunnel is set up in GTP kernel device
|
||||
`apn1`. For `access2`, use `apn2`.
|
||||
|
||||
=== netinst for tunmap
|
||||
|
||||
For the tunmap use case, it is sufficient to configure `netinst` entries, without any addition to the `tunmap` section.
|
||||
The following example configures various interfaces for tunmap, to match Network Instance names received in PFCP:
|
||||
|
||||
----
|
||||
tunmap
|
||||
table-name osmo-upf
|
||||
netinst
|
||||
add access1 10.0.0.1
|
||||
add access2 10.0.0.2
|
||||
add core1 9.0.0.1
|
||||
add core2 9.0.0.2
|
||||
----
|
||||
|
||||
For example, a Create PDR indicating a Network Instance of `core1` will result in an nftables rule that receives packets
|
||||
on local address `9.0.0.1`.
|
||||
@@ -11,6 +11,8 @@ include::{srcdir}/chapters/overview.adoc[]
|
||||
|
||||
include::{srcdir}/chapters/running.adoc[]
|
||||
|
||||
include::{srcdir}/chapters/netinst.adoc[]
|
||||
|
||||
include::./common/chapters/vty.adoc[]
|
||||
|
||||
include::./common/chapters/logging.adoc[]
|
||||
|
||||
Reference in New Issue