mirror of
https://github.com/tigerblue77/Dell_iDRAC_fan_controller_Docker.git
synced 2025-10-23 04:51:57 +00:00
@@ -46,6 +46,18 @@ then
|
||||
exit 1
|
||||
fi
|
||||
|
||||
# If server model is Gen 14 (*40) or newer
|
||||
if [[ $SERVER_MODEL =~ .*[RT][[:space:]]?[0-9][4-9]0.* ]]
|
||||
then
|
||||
DELL_POWEREDGE_GEN_14_OR_NEWER=true
|
||||
CPU1_TEMPERATURE_INDEX=2
|
||||
CPU2_TEMPERATURE_INDEX=4
|
||||
else
|
||||
DELL_POWEREDGE_GEN_14_OR_NEWER=false
|
||||
CPU1_TEMPERATURE_INDEX=1
|
||||
CPU2_TEMPERATURE_INDEX=2
|
||||
fi
|
||||
|
||||
# Log main informations
|
||||
echo "Server model: $SERVER_MANUFACTURER $SERVER_MODEL"
|
||||
echo "iDRAC/IPMI host: $IDRAC_HOST"
|
||||
@@ -138,15 +150,19 @@ while true; do
|
||||
fi
|
||||
fi
|
||||
|
||||
# Enable or disable, depending on the user's choice, third-party PCIe card Dell default cooling response
|
||||
# No comment will be displayed on the change of this parameter since it is not related to the temperature of any device (CPU, GPU, etc...) but only to the settings made by the user when launching this Docker container
|
||||
if $DISABLE_THIRD_PARTY_PCIE_CARD_DELL_DEFAULT_COOLING_RESPONSE
|
||||
# If server model is Gen 14 (*40) or newer
|
||||
if ! $DELL_POWEREDGE_GEN_14_OR_NEWER
|
||||
then
|
||||
disable_third_party_PCIe_card_Dell_default_cooling_response
|
||||
THIRD_PARTY_PCIE_CARD_DELL_DEFAULT_COOLING_RESPONSE_STATUS="Disabled"
|
||||
else
|
||||
enable_third_party_PCIe_card_Dell_default_cooling_response
|
||||
THIRD_PARTY_PCIE_CARD_DELL_DEFAULT_COOLING_RESPONSE_STATUS="Enabled"
|
||||
# Enable or disable, depending on the user's choice, third-party PCIe card Dell default cooling response
|
||||
# No comment will be displayed on the change of this parameter since it is not related to the temperature of any device (CPU, GPU, etc...) but only to the settings made by the user when launching this Docker container
|
||||
if $DISABLE_THIRD_PARTY_PCIE_CARD_DELL_DEFAULT_COOLING_RESPONSE
|
||||
then
|
||||
disable_third_party_PCIe_card_Dell_default_cooling_response
|
||||
THIRD_PARTY_PCIE_CARD_DELL_DEFAULT_COOLING_RESPONSE_STATUS="Disabled"
|
||||
else
|
||||
enable_third_party_PCIe_card_Dell_default_cooling_response
|
||||
THIRD_PARTY_PCIE_CARD_DELL_DEFAULT_COOLING_RESPONSE_STATUS="Enabled"
|
||||
fi
|
||||
fi
|
||||
|
||||
# Print temperatures, active fan control profile and comment if any change happened during last time interval
|
||||
|
@@ -38,10 +38,10 @@ function retrieve_temperatures () {
|
||||
|
||||
# Parse CPU data
|
||||
local CPU_DATA=$(echo "$DATA" | grep "3\." | grep -Po '\d{2}')
|
||||
CPU1_TEMPERATURE=$(echo $CPU_DATA | awk '{print $1;}')
|
||||
CPU1_TEMPERATURE=$(echo $CPU_DATA | awk "{print \$$CPU1_TEMPERATURE_INDEX;}")
|
||||
if $IS_CPU2_TEMPERATURE_SENSOR_PRESENT
|
||||
then
|
||||
CPU2_TEMPERATURE=$(echo $CPU_DATA | awk '{print $2;}')
|
||||
CPU2_TEMPERATURE=$(echo $CPU_DATA | awk "{print \$$CPU2_TEMPERATURE_INDEX;}")
|
||||
else
|
||||
CPU2_TEMPERATURE="-"
|
||||
fi
|
||||
@@ -58,11 +58,13 @@ function retrieve_temperatures () {
|
||||
fi
|
||||
}
|
||||
|
||||
# /!\ Use this function only for Gen 13 and older generation servers /!\
|
||||
function enable_third_party_PCIe_card_Dell_default_cooling_response () {
|
||||
# We could check the current cooling response before applying but it's not very useful so let's skip the test and apply directly
|
||||
ipmitool -I $IDRAC_LOGIN_STRING raw 0x30 0xce 0x00 0x16 0x05 0x00 0x00 0x00 0x05 0x00 0x00 0x00 0x00 > /dev/null
|
||||
}
|
||||
|
||||
# /!\ Use this function only for Gen 13 and older generation servers /!\
|
||||
function disable_third_party_PCIe_card_Dell_default_cooling_response () {
|
||||
# We could check the current cooling response before applying but it's not very useful so let's skip the test and apply directly
|
||||
ipmitool -I $IDRAC_LOGIN_STRING raw 0x30 0xce 0x00 0x16 0x05 0x00 0x00 0x00 0x05 0x00 0x01 0x00 0x00 > /dev/null
|
||||
|
Reference in New Issue